Sterilizing course selection
The optimal sterilizing course can be selected
from among five courses, such as the liquid sterilizing course in addition
to that for normal
sterilization
-
Liquid sterilizing course

This is most appropriate course setting for prevention of
sudden sample boiling.
-
Sterilizing course

Course for normal sterilization.
- Sterilizing-warming course

Prevents culture media from coagulating after sterilization.
- Heating-warming course

Extremely convenient for dissolving culture media and warming.
-
Memory
recall
Preferred operating conditions can be recalled up easily.
Easily
viewable “work monitor"
The LED display shows working status for easy monitoring. The process
being performed is indicated by an LED indication lamp blinking in
red.

* The illuminated display on the operating panel shown in the picture
is different from the actual display at the time of operation.
Timer
function
The operation starting time can be preset easily. By presetting the
start of operation, otherwise wasted periods at night or early morning,
can be used effectively.
Large indication
lamp “Operated"
An easily viewable large indication is provided at the
upper section of the operating panel. Depending on the pressure status
(normal pressure/pressure is applied), the displayed color changes.
Auto-variable exhaust speed
A function allowing the exhaust valve to open automatically after completion
of sterilization is provided. The exhaust speed can be set to one
of six levels (set to variable for liquid sterilization).
Lid interlock
A safety device (lid interlock mechanism) for locking the lid during
operation is provided. A high level of safety is assured to prevent
unanticipated accidents.
Setting to
100 degree celsius is possible
Variable temperature setting such as to 100 degree celsius as well as to 121 degree celsius
has been made possible. The temperature can be set within the range
from 45 degree celsius to 135 degree celsius in steps of one degree (heating mode up
to 104 degree celsius).
Water level detector
A safety device (water level detector) for preventing dry heating is
provided. The device is designed to detect the water level through
the micro electrolytes of the sterilizing water.
Pressure fine adjustment function
When the balance between the temperature and pressure deviates during
sterilization, fine exhausting is carried out automatically in order
to adjust the best chamber condition.
OPTION
External sensor for the articles to be sterilized
Sensor for directly detecting the temperature of articles to be sterilized. More
reliable sterilization monitor can be carried out.
Data output
The temperature data, pressure data, etc. can be exported. The temperature can
be recorded when the external recorder is connected.
External sensor and recorder
A temperature sensor and recorder independent of the autoclaves. The chamber
temperature can be recorded.