Sterilizing course selection
The optimal sterilizing course can be selected from among five courses, such as the liquid sterilizing course in addition to that for normal sterilization

- Liquid sterilizing course

This is most appropriate course setting for prevention of sudden sample boiling.

- Sterilizing course

Course for normal sterilization.

- Sterilizing-warming course

Prevents culture media from coagulating after sterilization.

- Heating-warming course

Extremely convenient for dissolving culture media and warming.

- Memory recall
Preferred operating conditions can be recalled up easily.

Easily viewable “work monitor"
The LED display shows working status for easy monitoring. The process being performed is indicated by an LED indication lamp blinking in red.

* The illuminated display on the operating panel shown in the picture is different from the actual display at the time of operation.

Timer function
The operation starting time can be preset easily. By presetting the start of operation, otherwise wasted periods at night or early morning, can be used effectively.


Large indication lamp “Operated"
An easily viewable large indication is provided at the upper section of the operating panel. Depending on the pressure status (normal pressure/pressure is applied), the displayed color changes.

Auto-variable exhaust speed
A function allowing the exhaust valve to open automatically after completion of sterilization is provided. The exhaust speed can be set to one of six levels (set to variable for liquid sterilization).

Lid interlock
A safety device (lid interlock mechanism) for locking the lid during operation is provided. A high level of safety is assured to prevent unanticipated accidents.


Setting to 100 degree celsius is possible
Variable temperature setting such as to 100 degree celsius as well as to 121 degree celsius has been made possible. The temperature can be set within the range from 45 degree celsius to 135 degree celsius in steps of one degree (heating mode up to 104 degree celsius).

Water level detector
A safety device (water level detector) for preventing dry heating is provided. The device is designed to detect the water level through the micro electrolytes of the sterilizing water.

Pressure fine adjustment function
When the balance between the temperature and pressure deviates during sterilization, fine exhausting is carried out automatically in order to adjust the best chamber condition.


OPTION

External sensor for the articles to be sterilized
Sensor for directly detecting the temperature of articles to be sterilized. More reliable sterilization monitor can be carried out.

Data output
The temperature data, pressure data, etc. can be exported. The temperature can be recorded when the external recorder is connected.

External sensor and recorder
A temperature sensor and recorder independent of the autoclaves. The chamber temperature can be recorded.

Accessories

Stainless Basket
Stainless Bucket
Stainless Long Basket
Stand for testing Durham's tubes
The entire basket is made of punched metal and is designed for easy penetration of steam. Bucket without holes to prevent leakage of liquid from articles being sterilized. Optimal for sterilizing the sterilizing bag. The structure of the lower section is without holes. Convenient for sterilizing test tubes containing culture media. Can be used as a stand independently.