The Flex-Spin Drive features a flexible motor shaft that equalizes minor imbalances without damaging the centrifuge or triggering the imbalance protection system. This allows excellent tolerance for minor difference in sample volumes.
Tomy offers a wide selection of Easy-Mount Rotors for the Flexpin Bench-top centrifuges. These rotors install and remove with the turn of a knob and the selection covers most of the commonly used centrifuge labware.
Tomy has developed a unique concept in imbalance protection based on the kinetic energy generated by the entire rotational system including the motor, rotor, buckets and adapters. This system, with its expanded inputs, is capable of detecting a severe imbalance within a few seconds after the centrifuge is started.


The TS - 38LB rotor and B438 - 96 buckets spin four 96 - well microplates at 4,200 rpm generating 3,100G ? sufficient for microplate based ethanol extractions of DNA.

The TLA-11 Fixed Angle Rotor is a high-speed rotor that takes up to six 35 to 50 ml conical centrifuge tubes, and generates up to 9,600G.
The maximum speeds will depend on the tube manufacturers' specifications.
No Chamber Gasket on the tabletop provides easy sample load.
LC-220 / 230
LC-200
※The indicator lights as shown differ from actual operation.
Programmable memory stores are provided.
Speeds are programmable in RPM or g values.
Common Jog-Dial and digital display simplify the control panel.
3 Acceleration and Deceleration steps (LC-220/230)
*2 Deceleration steps (LC-200)
| Model | LC-200 | LC-220 | LC-230 | |
| Maximum Speed | 9,000rpm |
|||
| Maximum RCF | 9,600G |
|||
| Maximum Capacity | 1,000ml (250ml x 4 places) |
1,200ml (15ml x 80 places) |
||
| Speed Control | Microprocessor |
|||
| Drive System | Flex-Spin Drive System |
|||
| Data Entry | Jog Dial |
|||
| Speed | Display/Display Range | Digital / 0 to 9,990rpm |
||
| Setting Range | 300 to 9,000rpm |
|||
| Control Precision | Setting Speed ±50rpm |
|||
| Force | Display/Display Range | Digial / 0 to 9,990G |
||
| Setting Range | 10 to 9,600G (Less than 300G:Units of 10G, More than 300G:Units 100G) |
|||
| Time | Display/Display Range | Digital / 0 to 99 minutes or Continuous |
||
| Setting Range | 1 to 99 minutes or Continuous |
|||
| Precision | Within 0.1% or 1 second |
|||
| Other Function | 3 Acceleration and Deceleration steps (LC-220/230)/2 Deceleration steps (LC-200), Rotor Speed Automatic Setting with BART Code, Previous Setting Memory, 5 Memory Stores (LC-220/230)/2 Memory Stores (LC-200) |
|||
| Safety Devices |
Imbalance Detector,
Scatter Containing Lid System,
Rotor Identification System,
Lid Interlock System,
Lid Detector,
Overspeed Detector,
Motor Overheat Detection,
Overcurrent Detection,
Circuit Detector
|
|||
| Required Environment | Room Temperature: 6 to 35°C, Relative Humidity: 30 to 85% |
|||
| Dimentions | 420W x 528D(projection 95) x 337H mm |
440W x 544D(projection 95) x 362H mm |
484W x 582D(projection 95) x 365H mm |
|
Height to the chamber: 300 mm |
Height to the chamber: 325 mm |
Height to the chamber: 328 mm |
||
| Net Weight | Approx. 46 kg |
Approx. 50 kg |
Approx. 54 kg |
|
| Power Required | 110/120V, 15A, 50/60Hz 220/230/240V, 10A, 50/60Hz |
|||
| Power Consumption(Calorific Value) | 470W (400kcal/h) |
600W (520kcal/h) |
730W (630kcal/h) |
|
| Accessories Included |
Operator's Manual,
Rotor Nut,
Warranty Card,
Customer Card,
BART Code Table
|
|||
* Specifications and design are subject to change for improvement without prior notice. Please ask for the latest specifications prior to your order and procurement.
|
* This document is created in the PDF file format. * To view PDF files, Adobe Reader or other software is needed. * If you don’t have Adobe Reader, click here to download its latest version. |
||||
![]() |
LC-200 / 220 / 230 (0.5MB) | |||