Digital Biology Home > Manufactured Products > Centrifuges > Suprema 25 / 23 / 21
[Centrifuges] Suprema 25 / 23 / 21

Quick Acceleration and Deceleration
SUPREMA series realize to shorten spinning time
and to speed up laboratory work.

Switch to Japanese Switch to Chinese

Line UP


  • Suprema 25
  • Suprema 23
  • Suprema 21

Accessories here

Acceleration and deceleration times are reduced by nearly 50%, compared to previous models. SUPREMA series minimize loss of operation time.

* Compared to the previous model with an equivalent rotor,
  acceleration and deceleration times are reduced with these percentages approximately.

User Friendly Front Indicator
The Front Indicator (green/red/orange line indicator) permits monitoring the operation status from a distance.

The green line indicator lights up when the system is turned on.

The red line indicator lights up while the rotor type is being identified or the rotor is spinning.

The orange line indicator flashes in case errors occur in the system and relevant error messages are displayed on the LCD.

Multiple memory functions
Easy-to-use and convenient LCD


The LCD display on the control panel features such special functions as history and memory functions as well as memory settings for information and operation conditions on the centrifuge program.

  • A simple memory function allows setting three operation conditions for each rotor.
  • 99 memory settings can be stored.

Sample temperature display

SUPREMA Series high speed refrigerated centrifuge control and maintain the sample temperature near the set temperature using the date from chamber temperature, rotor types and rotational frequency and display the value estimated from each data as actual sample temperature.

Suprema 25

  • Data Communications Fanction (factory option) An extemal output port for data communication is provided to output the data stored in memory such as centrifuging conditions and the various historical data to PC.
  • Programmed operation function
  • Several operation conditions can be programmed during a centrifuging operation and automatically executed in linear sequence. This function allows to store five programs in five different combinations.
  • Centrifugal acceleration integrator function
  • Capable of consecutive spins

10-step acceleration characteristics and 10-step and natural deceleration characteristics

The initial value of acceleration and deceleration characteristics is adjusted between 0 and 500 rpm, however, the function setting allows to set the adjustable rotation speed to the maximum speed of the rotor in use, adjustable in steps of 100 rpm.

Design incorporates friendliness to the global environment and safety

  • HFC R404A with the ODP = 0.0, which contains no chlorine to destroy the ozone layer, is used to reduce environmental impact.
  • Imbalance detection system: The system prevents operation when the rotor is unbalanced and the maximum permissible imbalance value is exceeded, and automatically slows the rotor down and stops.
  • Safety devices:
    Lid interlock, Lid Open/Close Detector, Overspeed Detector, Overcurrent Detector (power switch), Motor Overcurrent Detector, Temperature Error Detector (high or low temperature)

High-Capacity Angle Rotor series

1,000ml Large Volume Rotor

NA-610
1,000ml×6
7,000rpm/11,120G
Rotor for:Suprema25
NA-400
1,000ml×4
9,000rpm/15,220G
Rotor for:Suprema25/23 /21

Specifications

Model Suprema25 Suprema23 Suprema21
Maximum Speed
25,000rpm
23,000rpm
21,000rpm
Maximum RCF
60,110G (NA-6, NA-7)
51,420G (NA-1HS)
46,850G (NA-1HS)
Maximum Capacity
1,000ml x 6 tubes (NA-610)
1000ml x 4 tubes (NA-400)
Speed Control
Microprocessor
Motor
Induction Motor
Drive System
Direct Drive
Data Entry
Jog Dial
Speed Setting Range
0 ∼ 25,000rpm (100rpm increments)
0 ∼ 23,000rpm (100rpm increments)
0 ∼ 21,000rpm (100rpm increments)
RCF Setting Range
0 ∼ 60,110G (10G increments)
0 ∼ 51,420G (10G increments)
0 ∼ 46,850G (10G increments)
Temperature Setting Range
-9 to 35°C (1°C increment)
Time Setting Range
0 ∼ 50sec.(10sec. increments), 0:01 ∼ 9:59 (1min. increment), 10 ∼ 24hours (1hour increment), Free
Acceleration/
Deceleration Setting
Acceleration: 10 steps, Deceleration: 10 steps and Free
Memory Function
3 Memories for each rotor with Memory Keys and 99 Memories with Menu Key
Program Operation
Ο
-
RCF Integrated Operation
Ο
-
Continuous Flow Rotor
Ο
-
Other Function
Rotor Speed Automatic Setting with BART Code, Radius Setting, Date and Time Display
Safety Devices • Lid Interlock System, • Lid Open/Close Detector, • Overspeed Detector, • Imbalance Detector, • Overcurrent Detector, • Rotor Identification System, • Motor Overcurrent Detector, • Temperature Error Detector
Refrigerant
HFC R404A
Power Requirement
AC 220/230/240V, 50Hz, 30A
AC 220/230/240V, 60Hz, 30A
Rated Current
21A
21A
18A
Power Consumption(Calorific Value)
3.3kW (2,840kcal/h)
3.3kW (2,840kcal/h)
2.6kW (2,240kcal/h)
Dimensions W x D x Hmm
(Except projection)
715W x 795D x 1020H mm
(Height to Operation Table: 870Hmm)
570W x 795D x 1020Hmm
(Height to Operation Table: 870Hmm)
Net Weight
265kg
215kg
Accessories • Operator 's Manual 1, • Warranty Card 1, • Customer Card 1, • Inspection Sheet 1, • Clear Case 1, • Attachment Screw 1, • Level 1, • Special Tool for Continuous Flow Rotor Use (for Suprema 25) 1, • Rotor puller

* Specifications and design are subject to change for improvement without prior notice. Please ask for the latest specifications prior to your order and procurement.

See Catalog PDF for details.

* This document is created in the PDF file format.
* To view PDF files, Adobe Reader or other software is needed.
* If you don’t have Adobe Reader, click here to download its latest version.
PDF downroad Suprema 25 / 23 / 21 (1.3MB)
High-capacity angle rotor series  (1.19MB)