Quick Acceleration and Deceleration
SUPREMA series realize to shorten spinning time
and to speed up laboratory work.
* Compared to the previous model with an equivalent rotor,
acceleration and deceleration times are reduced with these percentages approximately.
The green line indicator lights up when the system is turned on.
The red line indicator lights up while the rotor type is being identified or the rotor is spinning.
The orange line indicator flashes in case errors occur in the system and relevant error messages are displayed on the LCD.
The LCD display on the control panel features such special functions as history and memory functions as well as memory settings for information and operation conditions on the centrifuge program.
SUPREMA Series high speed refrigerated centrifuge control and maintain the sample temperature near the set temperature using the date from chamber temperature, rotor types and rotational frequency and display the value estimated from each data as actual sample temperature.
The initial value of acceleration and deceleration characteristics is adjusted between 0 and 500 rpm, however, the function setting allows to set the adjustable rotation speed to the maximum speed of the rotor in use, adjustable in steps of 100 rpm.
1,000ml Large Volume Rotor
Model | Suprema25 | Suprema23 | Suprema21 |
Maximum Speed | 25,000rpm |
23,000rpm |
21,000rpm |
Maximum RCF | 60,110G |
51,420G |
46,850G |
Maximum Capacity | 1,000ml x 6 tubes |
1000ml x 4 tubes |
|
Speed Control | Microprocessor |
||
Motor | Induction Motor |
||
Drive System |
Direct Drive |
||
Data Entry | Jog Dial |
||
Speed Setting Range | 0 ∼ 25,000rpm (100rpm increments) |
0 ∼ 23,000rpm (100rpm increments) |
0 ∼ 21,000rpm (100rpm increments) |
RCF Setting Range | 0 ∼ 60,110G (10G increments) |
0 ∼ 51,420G (10G increments) |
0 ∼ 46,850G (10G increments) |
Temperature Setting Range | -9 to 35°C (1°C increment) |
||
Time Setting Range | 0 ∼ 50sec.(10sec. increments), 0:01 ∼ 9:59 (1min. increment), 10 ∼ 24hours (1hour increment), Free |
||
Acceleration/ Deceleration Setting |
Acceleration: 10 steps, Deceleration: 10 steps and Free |
||
Memory Function | 3 Memories for each rotor with Memory Keys and 99 Memories with Menu Key |
||
Program Operation |
Ο |
- |
|
RCF Integrated Operation | Ο |
- |
|
Continuous Flow Rotor | Ο |
- |
|
Other Function | Rotor Speed Automatic Setting with BART Code, Radius Setting, Date and Time Display |
||
Safety Devices | Lid Interlock System, Lid Open/Close Detector, Overspeed Detector, Imbalance Detector, Overcurrent Detector, Rotor Identification System, Motor Overcurrent Detector, Temperature Error Detector | ||
Refrigerant | HFC R404A |
||
Power Requirement | AC 220/230/240V, 50Hz, 30A AC 220/230/240V, 60Hz, 30A |
||
Rated Current | 21A |
21A |
18A |
Power Consumption(Calorific Value) | 3.3kW (2,840kcal/h) |
3.3kW (2,840kcal/h) |
2.6kW (2,240kcal/h) |
Dimensions W x D x Hmm (Except projection) |
715W x 794D x 1,017H mm (Height to Operation Table: 869Hmm) |
570W x 794D x 1,018Hmm (Height to Operation Table: 869Hmm) |
|
Net Weight | 265kg |
215kg |
|
Accessories | Operator 's Manual 1, Warranty Card 1, Customer Card 1, Inspection Sheet 1, Clear Case 1, Attachment Screw 1, Level 1, Special Tool for Continuous Flow Rotor Use (for Suprema 25) 1, Rotor puller |
* Specifications and design are subject to change for improvement without prior notice. Please ask for the latest specifications prior to your order and procurement.
* This document is created in the PDF file format. * To view PDF files, Adobe Reader or other software is needed. * If you don’t have Adobe Reader, click here to download its latest version. |
||||
![]() |
Suprema 25 / 23 / 21 (1.3MB) High-capacity angle rotor series (1.19MB) Suprema 25 / 23 / 21(Chinese) (2.26MB) |