Tomy has developed a unique concept in imbalance protection based on the kinetic energy generated by the entire rotational system including the motor, rotor, buckets and adapters.
This system, with its expanded inputs, is capable of detecting a severe imbalance within a few seconds after the centrifuge is started.
The Flex-Spin Drive features a flexible motor shaft that equalizes minor imbalances without damaging the centrifuge or triggering the imbalance protection system. This allows excellent tolerance for minor differences in sample volumes.
Tomy offers a wide selection of Easy-Mount Rotors for the LX/LIX Centrifuges. These rotors install and remove with the turn of a knob and the selection covers most of the commonly used centrifuge labware.
The TS-38LB rotor and B438-96 buckets spin four 96-well microplates at 4,200 rpm generating 3,100G - sufficient for microplate based ethanol extractions of DNA.
The TLA-11 Fixed Angle Rotor is a high-speed rotor that takes up to six 35 to 50 ml conical centrifuge tubes, and generates up to 9,600G.The maximum speeds will depend on the tube manufacturers' specifications.
The LX / LIX Centrifuges do not require a reargap for proper ventilation so they can be installed directly against the wall. Access to the chamber is at a comfortable 72 cm from the floor making easy to see and reach into the chamber.
The LX / LIX centrifuges feature a brushless, induction drive motor that is extremely quiet and maintenance-free.
The BART Code System offers greater precision for G-force calculations because it assigns a unique code based on each Bucket, Adapter, Rotor and Tube combination.
Converted values are displayed at the touch of a button and the centrifuge can be set to spin at either a specific rpm or G-force value.
* The indicator lights as shown differ from actual operation.
Two programmable memory stores are provided.
Speeds are programmable in rpm or G values.
Microprocessor Controlled (year 2000 compliant)
Common Jog-Dial simplifies the control panel
| Model | LX-141 | |
| Maximum Speed | 9,000rpm | |
| Maximum Force | 9,600G | |
| Maximum Capacity | 2,000ml (500ml x 4) | |
| Speed Control | Microprocessor | |
| Motor | Direct Drive / Induction Brushless | |
| Drive System | Flex Spin Drive System | |
| Data Entry | Jog Dial | |
| Temperature | Display/Display Range | Digital / -L· -9 to 63°C |
| Setting Range | -9 to 35°C | |
| Control Range | -9°C to Room Temperature | |
| Speed | Display/Display Range | Digital / 0 to 9,990rpm |
| Setting Range |
100 to 9,000rpm | |
| Control Precision | Setting Speed +/-50rpm | |
| Force | Display/Display Range |
Digital / 0 to 9,990G |
| Setting Range | 10 to 9,600G (Less than 100G : Units of 10G , More than 100G : Units of 100G) | |
| Time | Display/Display Range |
Digital / 0 to 99 minutes, Free |
| Setting Range | 1 to 99 minutes, Free | |
| Precision | Within 0.1% | |
| Other Function | Acceleration Steps : 3 Steps, Deceleration Steps : 3 Steps (Touch Key), Rotor Speed Automatic Setting with BART Code, 3 Memory Stores (Touch Key) |
|
| Safety Devices | Imbalance Detector, Interlock, Door Detector, Overspeed Detector, Circuit Detector, Overheat/cool Detector, Rotor ID, Electronic Braking | |
| Required Environment | Room Temperature : 10 to 40°C, Relative Humidity : 30 to 85% | |
| Dimentions | 585W x 775D x 865H mm | |
| Hight to the Chamber : 720 mm | ||
| Net Weight | Approx. 155kg | |
| Power Required | 110/120V, 20A, 50/60Hz 220/230/240V, 10A, 50/60Hz |
|
| Power Consumption(Calorific Value) | 1,150W (990kcal/h) | |
| Accessories Included | Operator's Manual, Clear Case w/Attachement Screw, Level, Wrench for Level Adjustment, Rotor Nut, Warranty Card, Customer Card, BART Code Table | |
* Specifications and design are subject to change for improvement without prior notice. Please ask for the latest specifications prior to your order and procurement.
|
* This document is created in the PDF file format. * To view PDF files, Adobe Reader or other software is needed. * If you don’t have Adobe Reader, click here to download its latest version. |
||||
![]() |
LX-141 (1.4MB) | |||