Low Speed Refrigerated Centrifuge AX-521 / 511 / 501

 

Low Speed Refrigerated Centrifuge AX-521 / 511 / 501

Low Speed Refrigerated Centrifuge

AX-521 / 511 / 501

Low Speed Refrigerated Centrifuge AX-521 / 511 / 501

Wide Variety of Rotors

A wide variety of tubes and plates, such as 1.5 / 2.0 ml microtubes, 15 / 50ml conical tubes, blood collection tubes, micro / deep well plates, 250ml bottles, etc., and angled and swing out type rotors are available in three models to suit your application.
  • Swing Out Rotors

    From micro tubes to 250ml bottles.
    • Swing Out Rotor TS-38C
      TS-38C
      Bucket B438,
      Tube Rack 3850-04P
      Conical 50ml × 16
      ConicalConical 50ml

    • Swing Out Rotor TS-7C
      TS-7C
      Bucket
      7115-08
      Conical
      15ml × 32
    • Swing Out Rotor TS-33C
      TS-33C
      Bucket B433
      250ml × 4
      Bucket Cap
      Kit B433 HS
    • Swing Out Rotor TS-37C
      TS-37C
      Bucket B437
      Tube Rack 3715-TC16P
      Conical
      15ml × 64
    • Swing Out Rotor TS-41C
      TS-41C
      Deep-well
      plate × 4
  • Angle Rotors

    Spinning maximum 10,000rpm (Angle rotors only).
    • Angle Rotor CA-16
      CA-16
      Conical 50ml × 8
      10,000 rpm
      11,740 G
    • Angle Rotor CA-5
      CA-5
      2ml × 24
      10,000 rpm
      9,390 G
    • Angle Rotor CA-14HS
      CA-14HS HS
      50ml / 14ml × 4
      10,000 rpm
      8,500 G (50ml)
      7,720 G (14ml)
    • Angle Rotor CA-15
      CA-15
      2ml × 18 or 0.5ml / 0.2ml × 12
      10,000 rpm
      8,500 G (2ml) / 6,600 G (0.5ml) /
      5,810 G (0.2ml)
HS This bucket, which has been tested and certified by the Health Protection Agency (HPA, UK) to be compliant with the International Standard (Annex AA of the IEC 61010-2-020), meets requirements for biohazard safety. HS It adopted a hermetically sealed structure equivalent to HS bucket or rotor designed and tested in accordance with the International Standard (Annex AA of the IEC 61010-2-020) to offer excellent sealing performance.

Swing Out Rotors Compatibility

CS-1 TS-4C TS-41C TS-7C TS-33C TS-38C TS-37C
Max.
10,000rpm
Max.
1,800rpm
Max.
4,400rpm*1
Max.
5,000rpm
Max.
4,800rpm*2
Max.
4,200rpm
Max.
3,200rpm
AX-501 2 ml
10,000rpm
Microplates Deepwell
plates
Ο Ο
AX-511 Ο Ο Ο
AX-521 Ο Ο Ο Ο
  • *
    Fixed angle rotors are available for all models.
  • *
    The above specifications show the maximum value of sped (rpm). These values may change according to the combination of rotor, bucket, adapter and tubes.
  • *1
    AX-501: Max.3,600rpm
  • *2
    AX-501: Max.4,100rpm

Rotors & Accessories
Selection Guide

User Friendly and Safety Features

Mix Bucket & Mix Rack & Multi Rack

  • when 15ml tubes and 50ml tubes load to swing out rotor
    Previous

    1 set of 15ml tube bucket / rack and 1 set of 50ml tube bucket / rack were required.
    Previous image
    Mix Bucket
    &
    Mix Rack
    Mix bucket / Mix rack can be loaded 15ml tube and 50ml tube mixed together.
    Mix bucket / Mix rack can be loaded 15ml tube and 50ml tube mixed together.
  • Bucket for TS-7C Swing Out Rotor
    Bucket 7M5015-1 for Swing Out Rotor TS-7C
    7M5015-1
    (Mix Bucket)
    (50ml × 1tube + 15ml × 4tubes) × 4
    Mix bucket can be loaded 15ml tube and 50ml tube mixed together.
    Mix bucket can be loaded 15ml tube and 50ml tube mixed together.
    50ml=50ml 15ml=15ml
    Rack for TS-38C Swing Out Rotor
    38M-TC0204P
    (Mix Rack for Conical Tubes)
    50ml × 2tubes × 4 or 15ml × 4tubes × 4
    Rack 38M-TC0204P for Swing Out Rotor TS-38C
    Mix rack can be used(50ml × 1tube +15ml × 2tubes) × 4!
    For example, Mix rack can be used(50ml × 1tube +15ml × 2tubes) × 4!
    50ml=50ml 15ml=15ml
    3810M-14P
    (Multi Rack for Blood Collection Tubes)
    5~10ml × 14tubes × 4

    Rack 3810M-14P for Swing Out Rotor TS-38C

Flex-Spin System for safer and more efficient operation

Innovative Flex-Spin System employed to maintain safe and efficient centrifugal operation allows a margin of error and eye-balancing of sample tubes.
  • *
    Some rotors are excepted.
  • Non-chlorine, ozone-friendly refrigeration medium which has zero ozone layer destruction coefficients is adopted.
  • Flex-Spin Drive

    The Flex-Spin Drive features a flexible motor shaft that equalizes minor imbalances without damaging the centrifuge or triggering the imbalance protection system. This allows excellent tolerance for minor differences in sample volumes.
  • One-push rotor locking knob

    With a single knob push, the rotor can be quickly and securely fixed.

    • *
      Some rotors are excepted.
    • To mount the rotor

      Pressing the red snap on the locking knob down

      Place the locking knob on the shaft and secure the rotor to the shaft by pressing the red snap on the locking knob down the shaft until it “clicks”.
    • To dismount the rotor

      Pull the locking knob out from the shaft

      Pull the locking knob out from the shaft, while holding down the red snap on the top.

Intuitive Display and Control Panel

LCD monitor display
1Easy-to-see LCD monitor display shows various information including remaining run time, error messages, rotor types in use and records of centrifugal operation. The monitor can display in English or Japanese. (AX-521)
  • *
    Indication displays on the control panel in the photo is different from displays of actual operation.
Dual color LED display allows the user to monitor the operation status just by looking the display
2Dual color LED display allows the user to monitor the operation status just by looking the display; red indicates that the rotor is spinning while green indicates the rotor is stopped.
3Popular user-friendly Jog Dial equipped with an <ENTER> button on top enables setting to be changed quickly and more surely.
  • Compact Design

    Compact Design
    More compact in design, compared with existing high capacity refrigerated centrifuge, is one of the many advantages of the AX series.
    AX Series are ideally suited for applications where space is limited.

    Convenient Flashing Function

    For quick spin-down.
  • Three-step acceleration and three-step and natural deceleration

    Three-step acceleration and three-step and natural deceleration
    Initial values for acceleration and deceleration characteristics are set from 0 to 500rpm, however, they can be varied up to maximum speed in 100rpm increments by function settings.

Environmentally Friendly

ECO mode

  • TOMY AX-Series new model is equipped with the power-saving [ECO] mode, reducing standby power consumption.
    [ECO] mode
    [ECO] key
    Activating the power-saving [ECO] mode can also help reduce the power consumption during the waiting time (standby cooling) by allowing the temperature control bands to be changed.The chamber can cool down to the set temperature within approximately 3 minutes and a half * after release from ECO mode.
    • *
      Under the conditions: set temperature of 4℃ at an ambient temperature of 25℃.
  • Power consumption at ECO mode

    Power consumption at ECO mode

    An overall increase in cooling efficiency allows for drastic reduction in energy usage during normal operation.
    • *
      Measurement conditions: Set to 4℃ at an ambient temperature of 25℃ while centrifugation is stopped.
      (Rotors in use: AX-521 / AX-321: TS-37C+3750-TC06P)
    • *
      The values shown above are average values obtained by measuring the units.

Specifications

Model AX-521 AX-511 AX-501
Low Speed Refrigerated Centrifuge AX-521 Low Speed Refrigerated Centrifuge AX-511 Low Speed Refrigerated Centrifuge AX-501
Maximum Speed 10,000rpm
Maximum RCF 11,740G
Maximum Capacity 1,536ml (8 × 96 × 2ml DW plate) 1,000ml (4 × 250ml)
Control System Microprocessor control (feedback system)
Drive Motor Induction motor
Drive System Flex-Spin drive system (Direct drive with an automatic alignment function)
Data Entry Jog Dial equipped with an <ENTER> button
Temperature Setting Range From -9℃ to +35℃ (1℃ increment)
Speed Setting Range 100 to 10,000rpm (100rpm increments)
RCF Setting Range 10 to 11,740G (10G increments for the range less than 300G, 100G increments for the range over 300G)
Time Setting Range From 10 sec to 50 sec, in 10 sec increments, from 1 min to 99 min, in 1 min increments
or <F–> for free
Safety Devices Imbalance detector, Lid interlock, Lid open / close detector, Abnormal speed detector,
Over-current circuit breaker, Rotor identification system, Motor over-current detector,
Abnormally high or low chamber temperature detector.
Additional Functions Three-step acceleration characteristics selection, Three memory function,
Three-step deceleration characteristics selection, FLASH (momentary spin) function,
Memory function for last run parameters, BART Code selection, Power saving (ECO) mode
Refrigerant HFC R404A (270g) HFC R404A (260g) HFC R404A (250g)
Rated Current 120V : 12A, 220 / 230 / 240V : 6A 120V : 10A, 220 / 230 / 240V : 5A
Power Requirements 1-Phase 50 / 60Hz AC120V 15A, 1-Phase 50 / 60Hz AC220 / 230 / 240V 8A
Power Consumption (Heat output) 970W (834kcal / h) 960W (826kcal / h) 760W (654kcal / h)
Breaker Rated breaking current 120V : 15A, 220 / 230 / 240V : 7.5A
Protection Against Electric Shock Class I
Dimensions (except protruding portion) 540W × 597D × 858H mm,
(table height; 750H mm)
510W × 567D × 858H mm,
(table height; 750H mm)
462W × 540D × 858H mm,
(table height; 750H mm)
Net Weight 111kg (120V)
116kg (220 / 230 / 240V)
107kg (120V)
112kg (220 / 230 / 240V)
99kg (120V)
104kg (220 / 230 / 240V)
Environmental Requirements Ambient temperature range:10 to 35℃, Relative humidity:30 to 85%, Atmospheric pressure:700 to 1,060hPa
Intended exclusively for use indoors, Overvoltage category: II, Pollution degree: 2
Accessories Included Operator’s manual × 1copy, BART Code table × 1pc, Clear storage case for operator’s manual ×
1pc, Attaching screw for clear storage case × 1pc, Spanner × 1pc, Level gauge × 1pc, Rotor
locking knob × 1pc, Drain plug × 1pc, Power cord × 1pc, Digital Warranty Information × 1copy.
  • *
    The above specifications show the maximum value of speed, RCF (G) and sample capacity. These values may change according to the combination of rotor, bucket, adaptor and tubes.

  • *
    This document is created in the PDF file format.
  • *
    To view PDF files, Adobe Reader or other software is needed.